Total-Room Ultraviolet Disinfector
(TRU-D)

Lumalier's extensive line of Indoor Air Quality (IAQ) and after-hour disinfection products now includes an advanced total-room, air and surface disinfection system and professional disinfection services.

Construction

  • Rugged, stainless steel, aluminum, and injection-molded polymer construction.
  • All units feature advanced shock-resistant CPU’s, calibrated UV sensor arrays, and solid-state electronics to insure rugged, long-term reliability.
  • Portable and easy to move with locking non-scar rubber casters and removable handle.
  • Removable hard case protects the TRU-D unit and lamps during transportation and storage.
  • Hard case cover includes remote-control storage and signage to act as an entry barrier during use.
  • Five-year replacement warranty on all mechanicals and electronics, one-year warranty on lamps.
  • 1504 nominal watts / 504 UV watts to exceed all microbial disinfection requirements.
  • Advance PureVolt® Solid state electronic UV ballasts are perfectly matched with twenty-eight (28) environmentally-friendly low-mercury Philips high-output twin-tube UV SteriLamps® for reliability, efficiency and germicidal effectiveness. 1250 inches of UV tube arc length. 9000 hour lamp life
  • The TRU-D does not generate or release ozone into the air space.
  • Simple 120V, 15A plug-and-go operation.
  • Enclosed dimensions = 69”H x 27”W (Width with removable handle = 53”), 158 lbs.

Disinfect an entire room with one portable,easy-to-use, self-monitoring device

  • Position the TRU-D near the center of the room; activate the UV cleansing energy disinfection process from outside the area using a wireless remote.
  • Removable, hard-case lamp and storage protectors serve as warning signage to prevent accidental exposure.
  • Once activated, an array of sensors measure the germicidal UV-C energy reflected back to the unit.
  • An onboard CPU calculates the time required to effectively provide 3 to 6 log disinfection to all shaded areas within the room. Progress information is displayed on the wireless remote.
  • Door sensors deactivate the unit if people attempt to enter a room during the disinfection process.
  • The TRU-D automatically powers down when the preferred germicidal disinfection rate is achieved. 3 to 6 log air and surface decontamination is achieved in 20-30 minutes, depending upon the degree of decontamination required and the area size and configuration of the area to be decontaminated. The disinfected area is ready for immediate occupation and use.

Ideal for surface disinfection in laboratories, operating suites, ICU, clinics, schools, high risk areas, and any highly susceptible surface.

Primary benefit is 3 to 6 log surface disinfection of entire area. Secondary benefit is airborne microbial disinfection and VOC removal within the space.

 

Technical Specs PDF

These download requires Adobe's Acrobat Reader.

Download the complete technical specifications.
Download a summary of method of area sterilization using ultraviolet radiation.
Comparison of UV C Light and Chemicals for Disinfection of Surfaces in Hospital Isolation Units
Download the complete user manual.

Ordering Information

Cat. No.
Length (with handle)
Height
Width
Nominal
Watts
UV-C
Watts
Lamps
(included)
Lamp
Hours
TRU-D
53”
1340mm
69”
1764mm
27”
687mm
1540
504
(28) PL-L TUV 55W
9000